<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>AC Source/Sink - Westek Electronics</title>
	<atom:link href="https://www.westek.com.au/category/products/parent-testing-and-measurement-equipment/child-testing-and-measurement-equipment-ac-source-sink/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.westek.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 02 Mar 2025 07:18:02 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.westek.com.au/wp-content/uploads/2024/11/site-icon-150x150.png</url>
	<title>AC Source/Sink - Westek Electronics</title>
	<link>https://www.westek.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>AC Source/Sink</title>
		<link>https://www.westek.com.au/ac-source-sink/</link>
		
		<dc:creator><![CDATA[Westek_admin]]></dc:creator>
		<pubDate>Sun, 09 Feb 2025 00:43:48 +0000</pubDate>
				<category><![CDATA[AC Source/Sink]]></category>
		<category><![CDATA[All Products]]></category>
		<category><![CDATA[Testing and Measurement Equipment]]></category>
		<guid isPermaLink="false">https://www.westek.com.au/?p=2080</guid>

					<description><![CDATA[<h4>Network Simulation / Bidirectional AC Source/Sink Systems</h4>
<p>The TS-AC-5445 and TS-AC-5446 series are advanced, high-performance AC source/sink systems designed for network simulation and bidirectional power applications. These systems are highly versatile, providing adjustable AC output with a range of power and frequency options, making them ideal for applications such as power supply testing, grid simulation, and renewable energy systems.</p>
<p>The post <a href="https://www.westek.com.au/ac-source-sink/">AC Source/Sink</a> first appeared on <a href="https://www.westek.com.au">Westek Electronics</a>.</p>]]></description>
										<content:encoded><![CDATA[<h5 class="wp-block-heading">Key Features and Benefits</h5>



<h6 class="wp-block-heading">Adjustable AC Source/Sink:</h6>



<p><strong>TS-AC-5445 (1~): </strong>Designed for single-phase applications with a rated power of up to 200 kVA.<br><strong>TS-AC-5446 (3~): </strong>Supports three-phase applications with a rated power of up to 500 kVA.<br><strong>Frequency Range: </strong>Adjustable from 16.7 to 800 Hz, accommodating a wide range of testing scenarios.</p>



<h6 class="wp-block-heading">Proven Reliability:</h6>



<p>The static AC source incorporates tried and tested components from UPS technology, ensuring reliable performance and durability.<br>Designed for easy maintenance with a clear, user-friendly layout and robust components.</p>



<h6 class="wp-block-heading">Advanced Control and Monitoring:</h6>



<p><strong>Sinusoidal Input Current: </strong>Ensures smooth and efficient power conversion.<br><strong>IGBT Rectifier: </strong>Provides high efficiency and fast response.<br><strong>Event Log: </strong>Keeps a record of operational events for diagnostics and maintenance.<br><strong>Adjustable Output: </strong>Both voltage and frequency are adjustable to meet specific application requirements.<br><strong>Interfaces: </strong>RS232 is standard, with optional interfaces including CAN-Bus, Ethernet, and external control panels.</p>



<h6 class="wp-block-heading">Bidirectional Capability (Optional):</h6>



<p>The RTS-AC models offer bidirectional power flow, enabling both sourcing and sinking of AC power. This feature is essential for applications requiring energy recovery or simulation of real-world grid conditions.</p>



<h6 class="wp-block-heading">Enhanced Short-Circuit Current (Optional):</h6>



<p>Options are available for increased short-circuit current capability, providing robust performance under fault conditions.</p>



<h6 class="wp-block-heading">Customization:</h6>



<p>Systems can be tailored to specific customer requirements, including special designs, sensor cables, and customized control interfaces.</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">Technical Specifications</h5>



<h6 class="wp-block-heading">Mains Voltage:</h6>



<p><strong>3-Phase: </strong>208/380/400/440/480/500/660/690 V (PE) ± 10%<br><strong>1-Phase: </strong>230/460 V (PE) ± 10%<br><strong>Frequency options: </strong>16.7 Hz, 50 Hz, or 60 Hz</p>



<h6 class="wp-block-heading">Output Voltage:</h6>



<p><strong>Range: </strong>10 – 600 V ±1%, fixed or adjustable<br>Available in 1- or 3-phase configurations<br>Custom voltage ranges available upon request</p>



<h6 class="wp-block-heading">Output Frequency Range:</h6>



<p>45-105 Hz, 195-805 Hz, 95-420 Hz<br>Custom frequency ranges available upon request<br><strong>Accuracy: </strong>±0.1% fs</p>



<h6 class="wp-block-heading">Rated Power:</h6>



<p><strong>1-Phase (TS-AC-5445): </strong>Up to 200 kVA<br><strong>3-Phase (TS-AC-5446): </strong>Up to 500 kVA</p>



<h6 class="wp-block-heading">Voltage Tolerance:</h6>



<p><strong>Static: </strong>±1% of the final value<br><strong>Dynamic:</strong> ±4% at 100% load change (up to 400 Hz), ±8% (400-800 Hz)<br><strong>Asymmetric Load:</strong> ±2% at 100% unbalanced load (LN)</p>



<h6 class="wp-block-heading">Response Times:</h6>



<p><strong>RMS Value Settling Time: </strong>&lt; 25 msec<br><strong>Instantaneous Value Settling Time:</strong> &lt; 4 msec</p>



<h6 class="wp-block-heading">Overload Behavior:</h6>



<p>150% for 1 minute<br>125% for 10 minutes<br>110% for 20 minutes</p>



<h6 class="wp-block-heading">Short-Circuit Behavior:</h6>



<p>2x rated current (1-phase)<br>2-4x rated current (3-phase)<br>Inverter stops after 5 seconds</p>



<h6 class="wp-block-heading">Waveform:</h6>



<p><strong>Shape: </strong>Sinusoidal<br><strong>Distortion Factor:</strong> ≤ 3% at > 100 Hz, ≤ 5% at lower frequencies</p>



<h6 class="wp-block-heading">Compliance and Standards</h6>



<p><strong>Low Voltage Directive: </strong>2014/35/EU<br><strong>EMC Directive: </strong>2014/30/EU<br><strong>RoHS Directive: </strong>2011/65/EU<br><strong>EMC Behavior: </strong>EN 62040-2, EN 61000-6-2, EN 61000-6-4<br><strong>Permissible Power Factor: </strong>Arbitrary, with power reduction for deviations from 0.8 ind.<br><strong>Permissible Crest Factor of Load Current: </strong>≤ 2.3 at 100% load</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<h5 class="wp-block-heading">General Data</h5>



<h6 class="wp-block-heading">Environmental Conditions:</h6>



<p><strong>Storage: </strong>+5 to +40 °C (EN 60721-3-1: 1K21 / 1M11)<br><strong>Transport: </strong>-45 to +70 °C (EN 60721-3-2: 2K12 / 2M4)<br><strong>Operation: </strong>+5 to +40 °C (EN 60721-3-3: 3K22 / 3M11)<br><strong>Humidity: </strong>5-85% relative, no condensation<br><strong>Pollution Level: </strong>2<br><strong>Installation Height: </strong>Up to 1000 m above sea level at rated load</p>



<h6 class="wp-block-heading">Protection Class:</h6>



<p><strong>Standard: </strong>IP 20 according to IEC 60529<br><strong>Painting: </strong>RAL 7035</p>



<h6 class="wp-block-heading">Cooling Type:</h6>



<p><strong>ON: </strong>Natural cooling<br><strong>AF: </strong>Enhanced cooling, depending on performance requirements</p>



<div style="height:20px" aria-hidden="true" class="wp-block-spacer"></div>



<p>The TS-AC-5445 and TS-AC-5446 series offer a comprehensive solution for network simulation and bidirectional AC source/sink applications. With customizable features, advanced control options, and proven reliability, these systems are well-suited for a wide range of demanding industrial and research applications. Whether for grid simulation, renewable energy systems, or power supply testing, these AC source/sink systems deliver the performance and flexibility needed to meet modern challenges.</p><p>The post <a href="https://www.westek.com.au/ac-source-sink/">AC Source/Sink</a> first appeared on <a href="https://www.westek.com.au">Westek Electronics</a>.</p>]]></content:encoded>
					
		
		